Illinois just moved its door monitoring deadline to 2034

Illinois published a new door lock monitoring proposal on October 9 that replaces the 2029 timeline with January 1, 2034, and the comment clock is already running. Plus: Mississippi bans remote elevator changes outright, and a Colorado county shows how to phase a three-car modernization.
THE SIGNAL
Illinois published its door lock monitoring proposal, and the date is now 2034
On October 9, the Illinois Elevator Safety Review Board published proposed amendments to the Illinois Elevator Safety Rules, 41 Ill. Adm. Code 1000, in the Illinois Register (Volume 50, Issue 41). The proposal incorporates newer national codes, including ASME A17.1 (2025), and it would require most existing elevators that do not have a door monitoring system to add one. The First Notice puts the compliance deadline at seven years from anticipated adoption.
The Office of the State Fire Marshal (OSFM) spells out who is covered in its elevator FAQs. The proposed requirement applies to automatic passenger and freight elevators with power operated car doors that are mechanically coupled to landing doors, when the car does not already have door lock monitoring. Those existing elevators would need monitoring compliant with ASME A17.1 (2025) by January 1, 2034. Elevators permitted for installation or alteration after the rule takes effect would need compliant monitoring at the time of that work. Cars that already have a monitoring system keep complying under the code edition they were installed under.
Door lock monitoring is the system that prevents a car from moving unless its doors are fully closed and locked. OSFM describes it as monitoring door position and stopping automatic operation when it detects a fault in door wiring, locks, contacts, or a door system bypass. The cost is not small. The First Notice estimates $10,000 to $25,000 per elevator to install a compliant system, and says the cost could increase depending on the specific elevator. OSFM also gives owners two paths: add a monitoring overlay to the existing controller, or alter and modernize the elevator. OSFM says it is highly unlikely any elevator would need a full modernization solely because of its age or vintage.
This is still a proposal, not a final rule. Comments are due no later than 45 days after the October 9 publication, which is November 23, 2026, to Blake Fawns at OSFM, by mail or at [email protected]. A public hearing is set for November 5, 2026 at 9:30 AM at 5860 W. 111th Street, Chicago Ridge.
What this means for you: If you own or manage Illinois elevators outside a local program that runs its own rules, do three things now. First, find out car by car whether you already have door lock monitoring; OSFM itself tells owners who are unsure to ask their elevator company, and you want that answer in writing. Second, put a placeholder range in your long-range capital plan using the state's own $10,000 to $25,000 per car estimate, not a guess, and note that the overlay path may cost far less than a modernization. Third, if the scope or the cost hits your portfolio hard, the comment window is your one cheap move: file by November 23 or attend the November 5 hearing. Do not budget to the old January 1, 2029 date from earlier coverage. The published proposal now on the table says 2034.
INDUSTRY WATCH
Mississippi adopted the 2025 code and banned remote elevator changes in the same bulletin
Effective October 5, 2026, Mississippi adopted ASME A17.1-2025 in full, with one hard variance. No licensed company or person may alter any conveyance from off site. That ban covers software updates, parameter adjustments, and programming changes, unless the person is physically on the property to witness and verify that the change leaves the car code compliant and safe. If your Mississippi contractor's pitch leans on remote diagnostics that write back to the controller, get the on-site procedure in writing before you sign.
Source: Mississippi Insurance Department, Conveyance Safety Division, Bulletin No. 2026-10
Mesa County is modernizing three elevators for $429,842, phased so the building never loses all of them
Mesa County, Colorado approved a $429,842.48 contract to modernize the three elevators at its Community Services Building, 510 29 1/2 Road. All three cars are more than 20 years old. The scope brings them to current standards and current ADA requirements, including new communication systems, and the work is phased over about 18 weeks so the elevators are not all out of service at once. Two are public elevators and one is freight. Steal the structure for your own project: one contract, a stated total, and a phase plan your tenants can read before the first car goes down.
Source: Mesa County, Colorado (county news release, Oct. 19, 2026)
THE DEEP CUT
Do your elevators already have door lock monitoring? Find out in one week
Most owners cannot answer this question today, and guessing is expensive. Run this audit before any code deadline lands on your building.
Start with a list. One row per car: address, state ID number, controller make and model, year installed, year of last alteration, and door type. Door lock monitoring only applies to automatic cars with power operated car doors mechanically coupled to the landing doors, so that last column cuts your list fast. Manual doors and cars outside that description come off the audit.
Next, ask your elevator contractor one question in writing, per car: does this car have a door monitoring system that complies with the ASME A17.1 edition it was installed under, yes or no, and what is the test procedure? A verbal answer at a service visit is not a record. If the answer is yes, ask for the written test procedure and where it is kept. Current code expects that procedure on site, and an inspector can ask for it. If nobody can produce it, treat the car as unconfirmed, not compliant.
Then check your own files. Pull the maintenance control program, the last two inspection reports, and any modernization proposals from the last five years. Monitoring shows up in those documents when it exists: a line item, a test entry, a controller feature. Silence across all three is a strong signal the car does not have it.
Now price the gap. For each unconfirmed car, get two written options: an overlay that adds monitoring to the existing controller, and the same work folded into a modernization if one is already planned inside the compliance window. Regulators in Illinois have said an overlay is a real path and that full modernization just for monitoring is highly unlikely. Your quotes should reflect that.
Finish with a one-page sheet per building: car, status, evidence, quote, and planned year. File it with your inspection records. When a deadline is final, when a buyer does diligence, or when an inspector asks, you answer from paper instead of memory. That sheet also stops the worst outcome: paying for monitoring twice because two vendors sold it under two different names.
Run your contract through the free Contract Scanner
Free tool: the Contract Scanner
Before you price a monitoring retrofit, check what your current agreement actually covers. Upload your service contract and the Scanner flags the code-compliance exclusions, the uncapped escalations, and the auto-renewal traps that decide who pays when a new rule lands.
P.S. Want more than a flag? The Decode report is a full line-by-line breakdown of your specific agreement, including the exclusions and the triggered-code exposure, for $29.